Windows – Setting Domain Time

Domain Time KB ID 0000112

Problem

If you have arrived here, you have either noticed that the time is wrong on your server(s) or client PC(s), or you have looked in the event viewer and seen one of the following events being logged. Event ID’s 12, 22, 29, 36, 38, 47, and 50.

Time Problem Events – On the PDC Emulator

Event ID 12 (W32 Time Time Provider NtpClient: This machine is configured to use {text omitted}, but it is the PDC emulator…).

Event ID 29 (The time provider NtpClient is configured to acquire time from one or more time sources…).

Event ID 36 (The time service has not synchronized the system time for 86400 seconds…).

Event ID 38 (The time provider NtpClient cannot reach or is currently receiving invalid time data from…).

Event ID 47 (Time Provider NtpClient: No valid response has been received from manually configured peer…).

Domain Time Problem Events – On Domain Members

Event ID 50 (The time service detected a time difference of greater than 5000 milliseconds for 900 seconds…).

Event ID 22 (The time provider NtpServer encountered an error while digitally signing the NTP response for peer…).

Solution : Domain Time Problems

Setting domain time is a TWO-STEP process, set the time correctly on the PDC emulator, then let the clients take their time from the PDC emulator.

Locate the PDC Emulator

1. On a domain controller, Windows Key+R > netdom query fsmo {Enter}.

2. Take note of the PDC name and go to that server.

NTP Firewall config (Domain Time)

1. Ensure UDP Port 123 is open outbound from the PDC Emulator. How this is done will vary depending on your firewall vendor. If you have a Cisco ASA or a Cisco PIX see my article here.

To Test Use NTPTool

Below either the port is blocked (or the hostname/IP of the external NTP server is incorrect);

This is how it should look, every-time you press query you should get a response, now you know the correct port is open;

Configure the PDC Emulator to collect Reliable Domain Time

There’s two ways to do this, 1. Use Group Policy, and 2. Use command line.

Setting PDC Emulator Time With Group Policy

Of course our PDC Emulator is also a domain controller, so we need to link a GPO to the domain controllers OU. But we dont want all DC’s getting their time from an external source, so we will create a WMI filter to ensure the policy will only apply to the PDC emulator server.

Administrative tools > Group Policy Management > WMI Filter > New > PDC-Emulator-Only > Add > Select * from Win32_ComputerSystem where DomainRole = 5 > OK.

Don’t panic if you see this error > OK > Save.

Create a new GPO linked to the Domain Controllers OU.

Change the policy so it uses your WMI filter;

Edit The Policy, and navigate to;

[box]Computer Configuration > Policies > Administrative eTemplates > System > Windows Time Service > Time Providers[/box]

Configure Windows NTP Client

Enable the policy > set the NtpServer setting to server-name(comma)stratum-type(space). If you get this wrong you wont sync, and you will see this error.

Enable Windows NTP Client

Enable the Policy (The server still needs to get its time from the external source!)

Enable Windows NTP Server

Enable the policy (The server also needs to provide time to the domain clients).

Save and exit the policy editor, then on the PDC emulator force a policy update  and resync the time. Finally run rsop to make sure the settings have applied.

Setting PDC Emulator Time From Command Line

 

1. On the PDC emulator Windows Key+R > cmd {Enter}.

2. At command line execute the following four commands;

[box]

w32tm /config /manualpeerlist:ntp2d.mcc.ac.uk /syncfromflags:manual /reliable:yes /update

net stop "windows time"

net start "windows time"

w32tm /resync 

[/box]

Note: If you are NOT in the UK or simply want to use a different NTP time server go here for alternatives.

3. Look in the servers Event log > System Log for Event ID 37.

 

---------------------------------------------------------------
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 37
Date: xx/xx/xxxx
Time: xx:xx:xx
User: N/A
Computer: {servername}
Description:
The time provider NtpClient is currently receiving valid time 
data from ntp2d.mcc.ac.uk (ntp.m|0x0|10.0.0.1:123->130.88.203.64:123).

For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. —————————————————————

4. You will also see Event ID 35.

---------------------------------------------------------------
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 35
Date: xx/xx/xxxx
Time: xx:xx:xx
User: N/A
Computer: {servername}
Description:
The time service is now synchronizing the system time with the time source 
ntp2d.mcc.ac.uk (ntp.m|0x0|10.0.0.1:123->130.88.203.64:123).

For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. —————————————————————

Step 2 Check the domain clients

This is all you should need to do, because, (by default) all Domain clients get their time from the PDC when they log on, but to check;

1. Windows Key+R > cmd {enter}.

2. Execute the following command;

[box] w32tm /monitor [/box]

3. You will see the time this client can see, on all the domain controllers.

[box]

C:Documents and SettingsAdministrator.yourdomain>w32tm /monitor
server-dc.yourdomain.co.uk [192.168.1.1]:
ICMP: 0ms delay.
NTP: +363.2032725s offset from server-pdc.yourdomain.co.uk
RefID: server-pdc.yourdomain.co.uk [192.168.69.6]
site2-dc.yourdomain.co.uk [192.168.2.1]:
ICMP: 70ms delay.
NTP: +0.0470237s offset from server-pdc.yourdomain.co.uk
RefID: dc.yourdomain.co.uk [192.168.69.4]
serverdc2.yourdomain.co.uk [192.168.1.4]:
ICMP: 0ms delay.
NTP: +0.0000553s offset from server-pdc.yourdomain.co.uk
RefID: server-pdc.yourdomain.co.uk [192.168.1.6]
server-pdc.yourdomain.co.uk *** PDC *** [192.168.1.6]:
ICMP: 0ms delay.
NTP: +0.0000000s offset from server-pdc.yourdomain.co.uk
RefID: scarp.mc.man.ac.uk [130.88.203.64]

[/box]

(In the case above the time on server-dc is way out, address that first – (it was an old Windows 2000 server and running “net time server-pdc” {enter} fixed it).

4. Once all the domain controllers have a time that’s accurate (like the last three in the example above), then proceed.

5. Execute the following commands on a client machine;

[box]

net stop "windows time"

net start "windows time"

w32tm /resync 

[/box]

6. The machines event log should show the following successful events;

Event ID 37 (The time provider NtpClient is currently receiving valid time data from..).

Event ID 35 (The time provider NtpClient is currently receiving valid time data from..).

Setting Domain Clients Time via GPO

As already outlined you should not need to do this, (as it’s the default setting,) but if there’s a problem you can force domain clients to look at your PDC emulator for reliable time.

Create a GPO, and link it to the OU containing the computers you want to sync’

Edit the policy and navigate to;

[box]Computer Configuration > Policies > Administrative eTemplates > System > Windows Time Service > Time Providers[/box]

Configure Windows NTP Client

Enable the policy > Set the NtpServer to {Your-PDC-Name},0x9  > Set the Type to NT5DS.

Enable Windows NTP Client

Enable this policy.

Testing Client NTP Settings

Either run;

[box]w32tm /query /status[/box]

Or run RSOP.

 

Related Articles, References, Credits, or External Links

PDC Emulator: PDC Emulator: Cannot Sync Time From External NTP Server

Cisco ASA – Configuring for NTP 

 

Windows – Error ‘A Good Time server could not be located’

KB ID 0000705

Problem

Seen when running dcdiag,

Error(s):

Starting test: Advertising
Warning: Server-Name is not advertising as a time server.
......................... Server-Name failed test Advertising

 

Running enterprise tests on : PeteNetLive.com Starting test: Intersite ……………………. PeteNetLive.com passed test Intersite Starting test: FsmoCheck Warning: DcGetDcName(TIME_SERVER) call failed, error 1355 A Time Server could not be located. The server holding the PDC role is down. Warning: DcGetDcName(GOOD_TIME_SERVER_PREFERRED) call failed, error 1355 A Good Time Server could not be located. ……………………. PeteNetLive.com failed test FsmoCheck

Solution

Note: Any one of the things below can cause this problem, I suggest you retry running dcdiag after each step until it runs without error.

1. In a windows domain, clients normally get their time from the domain controller that holds the PDC Emulator role. Locate that server and log on.

Locate your FSMO Role Servers

2. Now configure your PDC emulator to get its time from a reliable external source.

Windows – Setting Domain Time

3. If you have got this far, then should already have the windows time service running, check!

4. From command line, remove and reinstall the Windows time service with the following two commands.

[box]w32tm /unregister<br />w32tm /register[/box]

Note: It’s not unusual to see the following error after you issue a ‘w32tm /unregister’ command,

Error
The following error occurred: Access is denied (0x80070005)

If this happens don’t panic, open the services console (Press F5) and the Windows Time Service may have disappeared (if so re-register it). If not manually stop the Windows Time service and try to unregister again, then re-register.

WARNING: After doing this, you will need to set the time service to get reliable time from an NTP External Server again.

5. Press Windows Key+R > regedit {enter} > Navigate to the following registry key;

[box]HKLM > System > CurrentControlSet > services > W32Time > Parameters[/box]

Ensure the Type value it set to NTP, the restart the Windows time service and check again.

5. Whilst still in the registry editor navigate to;

[box]HKLM > System > CurrentControlSet > services > W32Time > Config[/box]
Set the AnnounceFlags value to 5.

6. Whilst still in the registry editor navigate to;

[box]HKLM > System > CurrentControlSet > services > W32Time > Time Providers > NtpServer[/box]

Make sure the Enabled value is set to 1 (one).

7. If the problem persists, on the PDC Emulator run gpedit.msc > Navigate to;

[box]Computer Configuration > Administrative Templates > system > Windows Time Service[/box]

Make sure ‘Global Configuration Settings’ is set to ‘Not Configured’.

Navigate to;

[box]Computer Configuration > Administrative Templates > system > Windows Time Service > Time Providers[/box]

Make ALL the settings are to ‘Not Configured’.

If you changed anything, run ‘gpupdate /force’ and try again.

8. On the PDC Emulator, Open a command window (Note: You must Run as Administrator!) > In the Computer Settings section locate all the policies that are applying to the server.

Note: As a shortcut to find the offending policy, you could run ‘gpresult /v > c:gpresult.txt’ then search that text file, for any instance of w32tm, (here’s an example).

As above navigate to;

[box]Computer Configuration > Administrative Templates > system > Windows Time Service[/box]

Make sure Global Configuration Settings is set to ‘Not Configured’.

Navigate to;

[box]Computer Configuration > Administrative Templates > system > Windows Time Service > Time Providers[/box]

Make ALL the settings are set to ‘Not Configured’.

If you changed anything, run ‘gpupdate /force’ and try again.

Related Articles, References, Credits, or External Links

NA