Event ID 10

KB ID 0000110

Problem

Event filter with query “select * from HP_AlertIndication” could not be (re)activated in namespace “//./root/CIMV2” because of error 0x80041010. Events may not be delivered through this filter until the problem is corrected.

This error has been caused by System Insight manager (usually on another machine).

Solution

1. On the affected machine, Start > Run > cmd {enter}

2. “C:WINDOWSsystem32wbemwbemtest.exe” {enter}

3. Connect to desired name space which will bee root/cimv2

4. Select “Enum Instances”

5. Type: __EventFilter

6. Click OK

7. Select the instance then select “delete”

Related Articles, References, Credits, or External Links

NA

Author: Migrated

Share This Post On