Event ID 1206 and 1204

KB ID 0000125 

Problem

Event 1206 and 1204

Solution

 Drive
Array Accelerator Battery Failed. The array accelerator
board attached to the array controller in Slot 3 is reporting
a battery failure.

and
/ or

Drive Array Accelerator
Status Change. The array accelerator board attached to the
array controller in Slot 3 has a new status of 4.
(Accelerator status values: 1=other, 2=notConfigured, 3=enabled,
4=tmpDisabled, 5=permDisabled)

The Battery Write back cache module in your raid card is
being reported as “Failed”.

Two possible fix’s

1. Go
to HP and do a search for EX040528_CW01 this article states
that this error can occur on HP Raid controllers that have
a firmware version before 2.48 – Download and install the
firmware upgrade (2.48 or above), Its just an exe file run
it and reboot.

if that
doesnt fix it………..

The BBWC is broken replace it.

Related Articles, References, Credits, or External Links

NA

Author: Migrated

Share This Post On